Home > Water Analysis Equipments > Multi–Parameter Meter

M510T Multi-parameter Analyzer

M510T Multi-parameter Analyzer

M510T Multi-parameter Analyzer

M510T Multi-parameter AnalyzerGENERAL FEATURES:Color High contrast LCD touchscreen, 4.3 inches.Intelligent operation sys
Contact Now
Detailed Product Description

M510T Multi-parameter Analyzer


GENERAL FEATURES:

  • Color High contrast LCD touchscreen, 4.3 inches.

  • Intelligent operation system provides features including user management, calibration management, electrode management, method management, data management, Log Management and etc.

  • Multi-reading feature allows auto-read, timed-read and continuous-read. 

  • Automatic/Manual temperature compensation ensures accurate results.

  • Auto-hold feature senses and locks the measurement endpoint.

  • Data Storage 1000 sets for each parameter (GLP-compliant).

  • Data analysis feature helps user review, compare and recalculate results.

  • Support for USB communication.

  • Auto-power off feature effectively extends the battery service life.

  • Reset feature automatically resumes all settings back to factory default options.

  • IP65 waterproof. The portable meter is suitable for fields measurements and out door measurements.

pH

  • 1-8 points calibration with Standard Recognition.

  • Selectable pH buffer groups, including USA, NIST, DIN, GB, MERK, JIS.

  • User-defined pH buffer or buffer group is supported.

  • Automatic electrode diagnosis with pH slope and offset display.

Ion

  • 1-6 points calibration.

  • Selectable measurement unit, including μg/L, mg/L, g/L, mmol/L, pX, ppm, etc.

  • Multi-measurement modes are supported, including Direct Reading mode, Standard Addition mode, Sample Addition mode and GRAN mode.

  • Over 10 methods are built-in, including F-, Cl-, Br-, I-, NO3-, BF4-, NH4+, K+, Na+, Ca2+, Cu2+, Pb2+, Ag+ and etc., user-defined method is supported.

Conductivity

  • 1-5 points calibration automatically recognizes the standard solutions.

  • Settable parameters, including cell constant, reference temperature (5/10/15/18/20/25°C), temperature compensation coefficient and TDS factor.

  • Temperature compensation type (none, linear, pure water).

DO

  • Support for air-saturated water or zero oxygen calibration.

  • Auto barometric pressure compensation

  • Manual Salinity Factor Correction

  • Selectable pressure unit, including kPa, mbar, Torr, Atm.

Includes

  • E-301-QC 3 in 1 pH composite electrode

  • DJS-1VTC EC electrode

  • DO-958-Q polarographic DO electrode

  • NIST pH standard solution(4.01, 7.00, 10.01) ,50ml/vial

  • Electrode holder

  • Silicone rubber case

  • Wristbands

  • Touch pen

  • Carrying case


Specifications:

Model

M510T

Parameters

pH/EC/ISE/DO/Temp. (mV/ORP/pX/Resistivity/TDS/Sal./DO Saturation)

pH

Range

-2.000 to 20.000 pH

Resolution

0.1, 0.01, 0.001pH

Accuracy

±0.002 pH

Calibration Points

Up to 8

Standard Customization

Yes

Calibration Reminder

Yes

Standard Recognition

USA, NIST, MERK, JIS, GB and DIN buffers

Slope Limit

Yes

mV/ORP

Range

-2000.00 to 2000.00 mV

Resolution

0.1, 0.01 mV

Accuracy

±0.1 mV or ±0.03%

EH ORP Mode

Yes

ORP Calibration Points

1 custom point (relative mV)

pX

Range

-2.000 to 20.000 pX

Resolution

0.1, 0.01, 0.001 pX

Accuracy

±0.002 pX

Calibration Points

Up to 6

ISE

Range

1.000e-9 to 9.999e+9

Units

mol/L, mmol/L, g/L, mg/L, μg/L, ppm, ppb

Resolution

Up to 4 significant digits

Accuracy

±0.3%

Calibration Points

Up to 8

Conductivity

Range

0.000 μS/cm to 3000 mS/cm

Resolution

0.001 μS/cm minimum,

various with range selection

Accuracy

±0.5% FS

Reference Temperature

5, 10, 15, 18, 20, 25 ºC

Calibration Points

Up to 5

Calibration Reminder

Yes

Standard Recognition

10μS/cm, 84μS/cm, 500μS/cm, 1413μS/cm, 12.88mS/cm; 146.5μS/cm, 1408μS/cm, 12.85mS/cm, 111.3mS/cm

Resistivity

Range

5.00 Ω·cm~100.0 MΩ·cm

Resolution

0.01 Ω·cm minimum

Accuracy

±0.5% FS

TDS

Range

0.000 ppm~1000 ppt

Resolution

0.001ppm minimum, changed with range

Accuracy

±0.5% FS

Salinity

Range

0.0~80.0 ppt

Resolution

0.1ppt

Accuracy

±1ppt

Dissolved

Oxygen Concentration

Sensor Type

Polarographic

Range

0.00 to 99.99 ppm

Resolution

0.01 ppm

Accuracy

±0.10 ppm 

Calibration Reminder

Yes

Calibration Points

Air-saturated water or zero point

Barometric Compensation

Yes

Manual Salinity Factor Correction

Yes

Saturation

Range

 (0.0 to 600.0)%

Resolution

0.10%

Accuracy

±2.0%

Temperature

Range

-10 to 135 ºC, 14 to 275 ºF

Unit

ºC, ºF

Resolution

0.1

Accuracy

±0.1ºC

Measurement

Reading Mode

Auto Read (Fast, Medium, Slow), Timed, Continuous

Reading Prompts

Reading, Stable, Locked

Temp. Compensation

ATC, MTC

Data management

Data Storage

1000 Groups

GLP Features

Yes

Inputs

pH Electrode

BNC(Q9)

DO with Temp. Probe

4-pin aviation connector

Conductivity with Temp. Probe

5-pin aviation connector

Outputs

USB

USB 2.0 flash memory device, PC, scanner

Display options

Backlight

Yes

Auto Shutdown

300, 600, 1200, 1800, 3600 sec., off

IP Rating

IP65

Date and Time

Yes

General

Power

Rechargeable Lithium battery, AC Adapter, 100-240V AC input, DC5V output

Dimensions

90×255×40 mm

Weight

500g (1.1 lb)

Dimensions (Carton)

490×410×220 mm

Weight (Gross)

5.5 kg


Contact Details
Other Products