Home > Water Analysis Equipments > Ise Meter > Bench Type Ion Meter

YD200 Lab. Water Hardness Meter

YD200 Lab. Water Hardness Meter

YD200 Lab. Water Hardness Meter

Introduction ●Benchtop meter for measurement of water hardness (the total concentration of calcium ion and magnesium ion). ●Electrode adopts model 601-F water hardness combination electrode with patent structure. It consists of measurem
Contact Now
Detailed Product Description

 Introduction

●Benchtop meter for measurement of water hardness (the total concentration of calcium ion and magnesium ion).
●Electrode adopts model 601-F water hardness combination electrode with patent structure. It consists of measurement electrode, reference electrode and temperature probe. Replaceable measuring head, steady potential, fast response, easy to use.
●Meter adopts intelligent chip design, automatic calibration, automatic temperature compensation, time display, data storage RS232 output, etc.
● Ability to switch among eight units: mmol/L, mg/L (CaCO3), mg/L (CaO), mmol/L (Boiler) and mg/L (Ca). Three options of three units: ºfH(France)、ºdH (Germany)and ºeH(UK) from WH-Link communication software.
●Equipped with B1、B2 and B3 calibration solution.
●Equipped with WH-Link communication software, connect testing data of meter to computer.

Specifications

Water Hardness
Measuring range
 
 
 
Resolution
Accuracy
Temp. compensation
Calibration Solution
 
 
 
Calibration Mode
(0 ~ 10)mmol/L;        (0 ~ 401)mg/L(Ca);
(0 ~ 1000)mg/L(CaCO3); (0 ~ 100)ºfH(France Degree);
(0 ~ 561)mg/L(CaO);    (0 ~ 56)ºdH(German Degree);
(0 ~ 20)mmol/L(Boiler);  (0 ~ 70)ºeH (England Degree)。
0.01 and 0.1 water hardness units
±5% FS
(5 ~ 50)℃((automatic))
B1 Calibration Solution — 2.00×10-2 mmol/L
B2 Calibration Solution — 2.00×10-1 mmol/L
B3 Calibration Solution — 2.00 mmol/L
(B3Calibration Solution also can be used for the soaking solution of electrode)
(a)B1/B2 Calibration—using B1 and B2 Calibration Solution,suitable for < 2.00×10-2 mmol/L low concentration water quality,for example, boiler
water.
(b)Calibration—using B2 and B3 Calibration Solution,suitable forgeneral water quality.
Temperature
Measuring range
Resolution
Accuracy
0 ~ 60℃
0.1℃
±0.5℃
Other Technical Parameter
Data storage

Content Storage

Communication Connector

Power

Dimension and weight

Quality and safe certificate
128 groups

serial number of measuring value, measuring value, units, temperature, ATC or MTC, date, time and calibration way.

RS232

DC9V

(160×190×70)mm/750g

IISO9001:2000 and CE

working conditions
Ambient temperature
ambient humidity
(5~35)℃
≤85%RH

Standard Kit Includes

1. Model YD300 water hardness meter

1set

2.Model 601-F water hardness electrode( With two measruing heads and one screw plug )

1pc

3. Model 602 Flexible electrode holder

1pc

4.250mL water hardness calibration solution (B1, B2 and B3)

1btl/each

5.20mL test cup

4pcs

6. Test cup pedestal

1pc

   
 

 

7. WH-Link communication software

1 pc

8. RS-232 communication cable 1pc
9. Operation manual 1book
Contact Details