Introduction
● Meter meets with the requirement of international GLP standards. Its features up to automatic calibration, automatic temperature compensation, data storage, timing measurement, clock display, RS-232 output, function setting and self-diagnose etc. |
● There are three different measurement modes: stable display mode; time measurement mode; continuous measurement mode. |
● Automatically recognize 13 kinds of pH buffer solution. User can choose anyone from four series of standard buffer solutions: Europe & USA series, NIST series, CHINA series and Self-defined series. |
● High purified water and ammonia added purified water pH measuring mode can be set up, especially suitable for electric power and petrochemical industry |
●With EH redox potential measuring mode can directly display ORP value which against standard potential of hydrogen electrode. |
● Equips new type of DO electrode which has function of automatic temperature compensation and automatic salinity compensation as well as automatic air pressure compensation inside meter to make DO measuring mode has temperature, air pressure and salinity automatic compensation, easy to use, accurate to measure. |
●Polarogram type DO electrode has special electrode calibration cap. Only needs 3 to 5 minutes for electrode polarization. Electrode adopts combination diaphragm cap which very convenient to use. Each DO electrode equips with three spare diaphragms caps. |
● Meter has the only product serial number. |
● Dustproof and waterproof meter meets IP54 standards. All sockets are seal protected by the silica gel caps. |
Specifications
pH
|
Measuring range
Resolution
Accuracy
Input current
Input impendance
Stability
Temp. compensation range
|
(-1.999 ~ 19.999)pH
0.1/0.01/0.001 pH
Meter:±0.002 pH, connect meter with electrode:±0.01pH
≤1×10-12 A
≥3×1012 Ω
±0.002 pH/3h
(0 to 100) ℃(automatic or manual)
|
mV
|
Measuring range(mV/ORP/EH)
Resolution
Accuracy
|
-1999.9mV ~ 0 ~ 1999.9mV
0.1mV
±0.03% FS
|
Dissolved Oxygen
|
Measuring range
Resolution
Accuracy
Response time
Residual current
Temp. compensation range
Salinity compensation range
Air pressure compensation
Automatic calibration
Electrode type
|
(0 ~ 40.00)mg/L(ppm) (0 ~ 200.0)%
0.1/0.01 mg/L(ppm) 1/0.1 %
Meter:±0.10 mg/L,connect meter with electrode:±0.40 mg/L
≤30 s(25℃, 90% response)
≤0.1 mg/L
(0 ~ 45)℃(automatic)
(0 ~ 45)ppt(automatic)
(80 ~ 105)kPa(automatic)
Air saturated by water; water saturated by air
Polarogram type
|
Temperature
|
Measuring range
Resolution
Accuracy
|
-10℃~ 110℃
0.1℃
5~ 60℃range:±0.4℃ other range:±0.8℃
|
Other Technical Parameters:
|
Data storage
Storage content
Power
Communication connector
Size and weight
Quality and safety certification
|
300 groups
Measuring value series number, measuring value, temperature, ATC or MTC state, measuring date and time
DC9V/300mA
RS232
160 × 190 × 70mm/880g
ISO9001:2008, CE and CMC
|
Working Condition
|
Environment temperature
Environmental humidity
IP rating
|
5 ~ 35 ℃(0.01grade) 15 ~ 30 ℃(0.001grade)
≤75%
IP54 Dustproof and waterproof
|
Standard Kit Includes
1. Model MP525 pH/ DO meter | 1set |
2. Model 602 flexible electrode holder | 1pc |
3. Model 901 intelligent stirrer | 1set |
4. 201T-M plastic pH/ATC three-in-one combination electrode | 1pc |
5.2503-C glass pH combination electrode | 1pc |
6. MP500 temperature electrode | 1pc |
7. DO500 DO electrode | 1pc |
8. pH standard buffer solution(pH4.00, pH7.00 and pH10.01/50mL) | 1btl/each |
9. 9V power adapter(meter use)e | 1pc |
10. 6V power adapter(stirrer use) | 1pc |
11. DO503 membrane cap(DO electrode use) | 3pc |
12. DO502 DO electrode inner solution(30mL) | 1btl |
13. Cathode polishing paper | 2pc |
14. B628 stirring bead | 3pc |
15.AA battery | 2pc |
16. RS-232 communication cable | 1pc |
17. MP525 communication software disk | 1pc |
18. Operation manual | 1unit |
19. Brief operation instruction | 1unit |
20. Packing List | 1pc |
Please Feel free to give your inquiry in the form below.We will reply you in 24 hours.